Net Optics 10/100BaseT Port Aggregator Tap

Net Optics’ Port Aggregator Tap is a simple plug-and-play solution addressing the fact that many monitoring systems, including most software-based solutions, only offer a single channel NIC, limiting full-duplex visibility. While adding a second NIC can help maintain data integrity and visibility, there is a tradeoff in flexibility and ease-of-use. An operating system and NICs that enable binding are often required to achieve the same functionality as the Port Aggregator Tap. In contrast, the Port Aggregator Tap requires no additional components or configuration on the monitoring devices.

Typically, full-duplex monitoring with a network tap requires two NICs (or a dual channel NIC) – one interface for each side of the tapped full-duplex connection. The Port Aggregator Tap combines these streams, sending all aggregated data out one passive monitoring port. The best part of this innovation is the onboard memory to make sure traffic isn’t dropped during bursts.

Buffering Prevents Lost Data


The Port Aggregator Tap is designed to handle the combined traffic of a single full-duplex link. Normally, the traffic should be below the receiving capacity of the NIC, that is, less than 10 or 100 Mbps.


When the traffic queue exceeds the capacity of the NIC, the Tap buffers the overflow of up to one megabyte per side of the full-duplex connection. For your convenience, the buffers clear automatically when the traffic volume falls below the receiving capacity of the NIC. For example, if there is a traffic burst and a tap connected to a 100 Mbps network port on a monitoring device is now receiving 140 Mbps of traffic, the Tap buffers data until the burst is over. The Tap then sends the buffered data to the monitoring device until the buffer is cleared.

Simple to Deploy

Net Optics Port Aggregator Tap is a simple plug-and-play solution addressing the fact that many monitoring systems, including most software-based solutions, only offer a single channel NIC, limiting full-duplex visibility. While adding a second NIC can help maintain data integrity and visibility, there is a tradeoff in flexibility and ease-of-use. An operating system and NICs that enable binding are often required to achieve the same functionality as the Port Aggregator Tap. In contrast, the Port Aggregator Tap requires no additional components or configuration on the monitoring devices.

Better than Span Ports

In the past, span ports were occasionally used to aggregate tapped traffic. However, in addition to other shortcomings of span port monitoring, span ports support very limited buffering and can simply drop data during bursts. The generous buffers of the Port Aggregator Tap prevent data loss in these conditions.

Zero Delay™ - A Net Optics Breakthrough


Highly sensitive network locations can improve monitoring performance via the innovative features of Net Optics Taps. If power is lost to other 10/100 Taps, the connected devices may introduce delays as they detect the power loss and try to re-establish their link.

Net Optics’ pioneering design ensures that any loss of power to the Tap is transparent to the network, and does not affect the flow of traffic through the Tap – eliminating packet delay and loss as potential security issues.

Security and Visibility

Without an IP address, monitoring devices are isolated from the network, dramatically reducing their exposure to attacks. However, the monitoring device connected to the Tap still sees all full-duplex traffic as if it were in-line, including Layer 1 and Layer 2 errors.

Simply Plug It In


Full-duplex monitoring is a snap when each side of the signal is sent to the same NIC on the monitoring device. All network and monitoring cables necessary for plug-and-play deployment are included with the Tap. Everything you need, right out of the box.


Reliability

For extra uptime protection, Net Optics Taps offer redundant power connections. Should the primary power source fail, the Tap automatically switches to the backup power source. Power LEDs on the front of the Tap indicate the current power source – even if power is lost and reapplied, there is always zero delay to network traffic.

Operating Specifications:
Operating Temperature: 0°C to 55°C
Storage Temperature: -10°C to 70°C
Relative Humidity: 10% min, 95% max, non condensing


Mechanical Specifications:

Power Supply:
Input: 100-240 VAC, 0.5A ~ 47-63Hz
Output: 12V, 1.5A
DC Power Supply: Input: -48V DC @ 5Amps
DC Receptacle: Terminal peak, 12-14 guage wire
Dimensions: 1.125" high x 9.125" deep x 4.5" wide
Weight: 2.15 Lb.


Cable Interface:

Copper Cable Type: 22-24 AWG unshielded twisted pair cable, CAT5/CAT5E
Link Distance Supported: 97.5 meters


Connectors:

(1) RJ45, 8 pin connector (Monitor Port, 1)
(2) RJ45, 8 pin connectors (Network Ports, A and B)


Certifications:

Fully RoHS compliant


Part Number:
PA-CU



Passive, Secure Technology

 

Supports passive, full-duplex monitoring with a single NIC, increasing monitoring efficiency.

One megabyte of memory for each side of the full-duplex link (two megabytes memory, total) prevents data loss during excessive traffic loads

Unique Zero Delay technology ensures every packet goes through without delay, even if power is lost to the Tap

Compatible with Mid-Span Power over Ethernet (PoE) applications

Provides complete full-duplex visibility at 10 or 100 Mbps without data stream interference or introducing a point of failure

Passes all traffic (including errors) from all layers for comprehensive troubleshooting

No IP address is needed for the Tap or monitoring device, enhancing monitoring security

Redundant power ensures monitoring uptime

Fully RoHS compliant


Warranty

 

All Net Optics products come standard with a 1 year manufacturer's warranty

Optional 1 or 2 year extended warranty available at time of product purchase

 

Ease of Use


LED indicators show redundant power, speed, link, and activity status

DIP switches enable selection of auto-negotiation or fixed speed and duplexing settings for the Tap

Front-mounted connectors support easy installation and operation

All network and monitoring cables included

Optional 19-inch rack frames hold up to three Taps

Tested and compatible with all major manufacturers' monitoring devices, including protocol analyzers, probes, and intrusion detection/prevention systems



Part Numbers

10/100 Port Aggregator Tap

- PA-CU
 
Port Agg, Copper, 10/100, Zero
  Delay

- PA-CU-DC
 
Port Agg, Copper, 10/100, Zero
  Delay  (-48V)

- RK-3V2

  Rack Panel Frame, 3-Slot 19"

- RK-12V2

  Rack Panel Frame, 12-Slot 19"

Net Optics - manufacturer of iTap™ - 10/100/1000 - GigaBit Network Taps, 10/100 - GigaBit Aggregator Taps, TX-SX, LX-SX All Converter Taps, IPS & IDS Bypass Switches, Matrix Switches and Teeny Tap™.

Resources

net_optics_evaluation.html
net_optics_register.html
net_optics_quick_quote.html

For more information, pricing, demonstration or evaluation on Net Optics Products please contact us here.

Questions? Call  1-805-277-2400

 
/body>